BLUE-FIRE FOUR CHANNEL
|
Four Channel Ignition Amplifier. |
Overview | Specifications |
Introducing the Blue-Fire
|
![]() |
Each channel LED (Blue) :
- ON : For duration of dwell current
Normal Operation
On receiving a positive input signal the corresponding output is switched on, and the Blue LED is on. Should an over-current develop before the input signal is switched on, the unit will TERMINATE the output, which will cause a spark. This action is indicated on the red LED which stays on for more than one ignition cycle.
If the same channel is operated again into an over-current (or short) then the above procedure repeats.
If the input is high for more than 50 milliseconds then the output is terminated, which causes a spark. This action flashes the red LED.