TF10 TECHNICAL MANUAL

Perfect Power Online Manuals.

 

Support for your TF10 Unit.

ANALOG #1 MODIFICATION

The TF10 ANA1 feature can modify one analog signal, namely ANALOG#1 INPUT  and output the mapped signal on ANALOG#1 OUT.

TF10 Turbo Fueller - F3 - Analog #1 Map

  • Main ANALOG Map : 384 sites via TPS and RPM, entry in counts, i.e. 100 counts = 1.0 Volts.
  • Optional : Air Temperature - 24 sites via Air Temp, entry in counts, i.e 100 counts = 1.0 Volts.
  • Engine Temperature - 24 sites via Engine Temp, entry in counts
  • AMP - 24 sites via AMP, entry in counts


Note : All maps can have positive or negative entries!

 

 

COMPLETE CALCULATION

 

 

ANA1OUT = ANA1IN
+- ANA1 MAP
X AN1 AMP
+- AN1 ENGT
+- AN1 AIRT

 


The ANA1OUT signal is limited to the low and high limits.

 

Note : The AMP map is a multiplier so when it is not used set all the values to 1

 

The analog 2 channel is calculated in the same manner.